Port BUSACCESS - LIN

VECTOR-SIL-KIT access to LIN

Stimulation

此端口不具备激励能力。

Name

在以下情况下可用

默认值

有效值

Type

Description

Network name

string

Name of the network as defined in SIL-Kit Config yaml.

Controller name

string

Name of the controller as defined in SIL-Kit Config yaml.

Baud rate

19200

float

Baudrate. Numbers lesser than 100 are interpreted as kbit/s, numbers larger than 100 as bit/s

Do not stop RBS

☐

bool

Restbus simulation stays active beyond test case execution.

LIN version

‘1.3’

[‘1.3’, ‘2.0’]

string

LIN protocol version to be used. Only affects calculation and validation of the frame checksum.

1.3 = received frames must have a classic checksum.

2.0 = received frames may have enhanced or classic checksum.

If the database does not define a checksum mode for a specific frame to be sent, this option will be taken into account to use either classic (1.3) or enhanced (2.0) checksum mode.

LIN master

☐

bool

Selection whether the port acts as a master (True) or a slave (False).

Bus-DB

string

ClearFrame

清除指定帧的接收缓冲区

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameId

int

Frame ID

返回值

Name

在以下情况下可用

默认值

有效值

Type

Description

result

ByteStream

ByteStream

DeregisterFrameForInbox

Ungeristers a frame that is being streamed to an inbox

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameId

int

Frame ID

Inbox

object

现有收件箱

EnableFrame

Makes this slave respond (or not respond) to the specified ID. You can use this instead of “Change PDU timing”. The frame must have been initialized via “InitFrame”.

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

enable

[False, True]

bool

Enable or disable

frameId

int

Frame ID

GetFirstValue

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameName

string

Frame name

NodeName

string

电子控制单元的名称

RawValue

False

[False, True]

bool

如果为 ‘True’,则返回原始值。

Reset

False

[False, True]

bool

若为 ‘True’,则第一个接收到的值在被读取后将被删除

SignalName

string

信号名称

InitFrame

Registers the frame for use with other jobs

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameId

int

Frame ID

ReadFrame

Reads the given frame ID (use InitLinFrame before!)

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

doDelete

False

[False, True]

bool

若为 “True”,则在读取后删除该帧

FrameId

int

Frame ID

返回值

Name

在以下情况下可用

默认值

有效值

Type

Description

result

ByteStream

ByteStream

ReadFrameEx

Reads the given frame ID (use InitLinFrame before!)

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

doDelete

False

[False, True]

bool

若为 “True”,则在读取后删除该帧

FrameId

int

Frame ID

返回值

Name

在以下情况下可用

默认值

有效值

Type

Description

result

object

LinFrame

RegisterFrameForInbox

注册一个帧,以便将其流式传输到 Inbox。

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameId

int

Frame ID

Inbox

object

现有收件箱

saveAsLinFrame

False

[False, True]

bool

If True, the frame is saved as a LinFrame object, else as a ByteStream

ResetFirstValue

清除给定信号的第一个已接收值

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameName

string

Frame name

NodeName

string

电子控制单元的名称

SignalName

string

信号名称

SendFrame

All in one: Set data, temporarily enable a frame, and send a master request. Frame ID must be registered in advance via the job “InitFrame”.

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

checkSumMode

‘Default’

[‘Enhanced’, ‘Classic’, ‘Default’]

string

Mode of the checksum calculation. With default the LIN version from the TBC is used for the determination.

DataByteStream

ByteStream

要发送的数据

FrameId

int

Frame ID

SendMasterRequest

Transmits the message header with the given frame id as master.

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

frameId

int

Frame ID

SetFrame

Sets the data to be sent for the entire message at once (instead of for each individual signal). Additionally, the message has to be activated via “Change PDU timing” or the job “EnableFrame”.

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

checkSumMode

‘Default’

[‘Enhanced’, ‘Classic’, ‘Default’]

string

Mode of the checksum calculation. With default the LIN version from the TBC is used for the determination.

data

ByteStream

Data as ByteStream

frameId

int

Frame ID