供应商信息
Vendor |
Web page |
产品名称 |
Version |
|---|---|---|---|
Accurate Technologies Inc. |
VISION |
4.1.4, tested up to 7.0.2 |
Categories
MDL 🛈 |
APL 🛈 |
BAN 🛈 |
BMA 🛈 |
SVC 🛈 |
DGN 🛈 |
FIU 🛈 |
EES 🛈 |
FCT 🛈 |
DBG 🛈 |
IMG 🛈 |
AUDIO 🛈 |
ENVSIM 🛈 |
ENVCOM 🛈 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
✓ |
Platform
操作系统 |
Support |
|---|---|
Windows |
✓ |
Linux |
Ports¶
Specifics¶
Initial Setup
You need to set the Project file path property to select a proper configuration (*.vpj). All other settings are optional.
Notes for using the VISION UI
Although ecu.test starts VISION if it is not opened yet, it is started in a headless mode without UI in this case. If you want to see what is going on in VISION, you need to open VISION manually in advance.
Info
Reading and recording the running value of a curve or map is supported.
Properties 🛈¶
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
Project file path |
string |
Path to the project including the file (*.vpj). Path can be absolute or relative to the tool host base path. |
|||
Reload project |
☑ |
bool |
Also Reload project when it was already opened. |
||
Go Online |
☑ |
bool |
Automatically start the device communication. |
||
Activate auto-download |
☐ |
bool |
Specifies whether updated calibration values shall be downloaded to the devices automatically. |
||
Deactivate popup window |
☐ |
bool |
Suppress all ATI VISION popup windows during execution? |
||
Recording formats |
‘MDF4’ |
[‘MDF3’, ‘REC’, ‘MDF3+REC’, ‘MDF4’] |
string |
In which formats should recordings be made? MDF3 and MDF4 are supported by trace analysis. |
|
Maximum recording duration |
‘2h’ |
string |
PostTriggerPeriod. Sometimes needs to be lowered to make fast recording rates possible. |
||
Group separator |
‘#’ |
[‘#’, ‘_’, ‘|’, ‘:’, ‘,’, ‘$’, ‘;’, ‘.’] |
string |
The native “.” separator for variable names is replaced by the group separator. |
|
Timeout for tool call ❲in sec.❳ |
‘600’ |
string |
工具调用被中止前的超时时间。 |
Jobs 🛈¶
IsOnline¶
Returns ‘True’, if device communication is enabled and ‘False’ otherwise.
Parameterization
返回值
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
state |
☐ |
bool |
Device communication state |
SetOnlineState¶
Enables/disables the device communication.
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
state |
‘Online’ |
[‘Online’, ‘Offline’] |
string |
Device communication state |