Vector: SIL Kit

供应商信息

Vendor

Web page

产品名称

Version

Vector Informatik GmbH

https://github.com/vectorgrp/sil-kit/

The Vector SIL Kit

v4.0.19,已测试至 v5.0.6

Categories

MDL 🛈

APL 🛈

BAN 🛈

BMA 🛈

SVC 🛈

DGN 🛈

FIU 🛈

EES 🛈

FCT 🛈

DBG 🛈

IMG 🛈

AUDIO 🛈

ENVSIM 🛈

ENVCOM 🛈

✓

✓

✓

✓

✓

✓

Signal recordings(信号记录) 🛈

文件格式

Comment

*.asc

*.mf4

BUSACCESS - CAN(-FD) 端口仅支持 MDF4 总线日志。XCP 端口支持基于信号的 MDF4 记录。

*.pcapng

BUSACCESS - CAN(-FD) 端口将使用 linktype=227。生成的文件无法由 Trace Analysis 处理。

Platform

操作系统

Support

Windows

✓

Linux

✓

Info

This tool can be configured and used multiple times in parallel.

Ports

Info

带有 ✦ 标记的端口属于 Add-on ecu.test calibration(需要单独的许可证)

Specifics

This interface allows direct access to simulated Ethernet as well as CAN, CAN-FD, LIN and FlexRay buses. It supports the test steps read signal, read/write signal group (all bus systems) as well as monitor (CAN, CAN-FD, LIN and FlexRay) and supports signal recording (all bus systems), Raw diagnostics with KWP2000 over ISO-TP (CAN only), the Mini residual bus simulation (CAN, CAN-FD and FlexRay) and Additional functions of the close-to-hardware bus connections (all bus systems).

目前仅支持 autonomous 生命周期模式。

Prerequisites

  • The Vector SIL Kit must be available on the tool host. As it will not be installed, but extracted to an arbitrary folder, the path to SilKit.dll (Windows) or libSilKit.so (Linux) has to be entered in the TBC editor at tool level.

  • ecu.test will not attempt to start the SIL Kit registry, but expects it to be already running and available under the URI specified in the TBC.

Note on the use of ethernet ports

In order to exchange ethernet packets with other SIL Kit participants, the name of a suitable network as well as an arbitrary controller name must be entered in the TBC.

Info

Further informationen about the purposes of the various Ethernet port types and their differences can be found in the description of the tool adapter tracetronic: Ethernet. All those not ending in -RAW here except ARP correspond to a similarly named type with the suffix or infix -PCAP there.

Note on the use of FLX ports

FlexRay ports can only communicate if SIL Kit runs a detailed simulation using the NetworkSimulator. The NetworkSimulator is not part of the SIL Kit itself, but can be obtained from Vector Informatik GmbH.

Enable simulation time in ports

In order to use the simulation time in the ports, a MODELACCESS - DEFAULT port must be created and the tool option enable model time must be set to True. Without this selection, system time will be used rather than simulation time.

Simulation time control

另请参见 时间模式的细节。

In order to use the simulation time in the test case, a MODELACCESS - DEFAULT port must be created and used in the TCF. In particular, it has to be configured on the Platform tab for Model access (but a Model is not necessary). It can then be defined on the tab Execution as the Temporal behavior source.
Without this selection, system time will be used rather than simulation time.

The following points should also be noted:

Stepwise execution in simulation time

This mode is currently not supported.

在仿真时间中连续执行

In this mode, a SIL Kit participant created for that purpose streams the current simulation time to ecu.test. The simulation time affects the test case itself (e.g. Wait test steps or time options of evaluations). Furthermore, simulation time is applied within Ethernet communication protocols to fulfill cycle times, observe timeouts etc.

Name

在以下情况下可用

默认值

有效值

Type

Description

SIL Kit Library Path

string

Path to SilKit.dll or libSilKit.so, as an absolute path or relative to the tool host’s base path

SIL Kit Registry URI

‘silkit://localhost:8500’

string

URI to the Sil Kit Registry Server

Activate model time

☐

bool

Use model time for all ports. When activated, a model port must be configured in the SIL Kit.

Timeout for tool call ❲in sec.❳

‘600’

string

工具调用被中止前的超时时间。

ClearArpCache

Clears all entries from the internal ARP/NDP cache