NI: VeriStand

供应商信息

Vendor

Web page

产品名称

Version

National Instruments

http://www.ni.com

VeriStand

From 2021

Categories

MDL 🛈

APL 🛈

BAN 🛈

BMA 🛈

SVC 🛈

DGN 🛈

FIU 🛈

EES 🛈

FCT 🛈

DBG 🛈

IMG 🛈

AUDIO 🛈

ENVSIM 🛈

ENVCOM 🛈

✓

✓

Platform

操作系统

Support

Windows

✓

Linux

Ports

Specifics

To write a model parameter, you can use the variables in the tree node “<Model Parameters>”. These variables are also listed in VeriStand in the “Model Parameter Manager”. After writing a variable, it can take a view milliseconds until the new value can be read from the signal. Parameters can not be recorded.

Aliases can be accessed via the tree node “<Aliases>”. For aliases that point to a model parameter, direct writing is not supported. Please use the node “<Model Parameters>” to manipulate such values.

借助节点 “<Channel Fault Manager>”可以将信号强制为特定值。通过向该节点下列出的量写入数据,即可对相应信号施加故障。此后对该信号的 Read 测试步骤将始终返回指定的值。对发生故障的通道执行 Reset 步骤可清除该故障,之后读取时将再次返回信号的真实值。有关 Channel Fault Manager 用法的更多信息,请参阅 VeriStand 帮助。

支持的 Project 文件

Veristand 提供两种项目文件格式(.nivsproj、.nivsprj)。尽管 nivsproj 文件已被声明为旧版格式,但只有这些文件包含 ecu.test 所需的 Python 包装器。较新的项目格式无法使用。打开项目时,Veristand 会自动在原始项目旁另存一个旧格式的项目。

更多信息可在 NI 网站上的 FAQ 中找到。

Name

在以下情况下可用

默认值

有效值

Type

Description

Version

[ONLINE]

string

Version of VersiStand

Project file

uri

Project file (*.nivsproj) as an absolute path or relative to the base path of the tool host.

User name

‘Administrator’

string

User login

Password

string

Password for user

Deploy at start

☑

bool

Load system definitions at start to the real-time computer.

Open workspace after connect

☐

bool

If this option is set to True, the workspace will be opened automatically after connecting with VeriStand.

Open project explorer after connecting

☐

bool

If this option is enabled, the Project Explorer is displayed, otherwise not.

Access timeout in ms

300000

int

Timeout for waiting of a VeriStand API response.

Sample rate for recording

1000

float

Record with the specified frequency in Hz. If the value is greater than the model’s sample rate, all samples will be recorded.

Undeploy project on disconnect

☐

bool

Enabling this option causes the VeriStand project to be undeployed when ecu.test disconnects.

Close project on disconnect

☑

bool

Enabling this option causes the project in VeriStand to be closed on disconnect from ecu.test.

Close tool on disconnect

☑

bool

Enabling this option causes VeriStand to be closed on disconnect from ecu.test.

Sampling rate ❲1/second❳ for playing stimuli

1000

int

When stimulated, the STI file is translated into a list of timestamps. This setting determines how many entries should be created per second.

Timeout for tool call ❲in sec.❳

‘600’

string

工具调用被中止前的超时时间。