EMVA: GenICam¶
供应商信息
Vendor |
Web page |
产品名称 |
Version |
|---|---|---|---|
european machine vision association |
GenICam |
2024.04 |
Categories
MDL 🛈 |
APL 🛈 |
BAN 🛈 |
BMA 🛈 |
SVC 🛈 |
DGN 🛈 |
FIU 🛈 |
EES 🛈 |
FCT 🛈 |
DBG 🛈 |
IMG 🛈 |
AUDIO 🛈 |
ENVSIM 🛈 |
ENVCOM 🛈 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
✓ |
Platform
操作系统 |
Support |
|---|---|
Windows |
✓ |
Linux |
✓ |
Ports¶
Specifics¶
The GenICam standard enables cameras and frame grabbers from different manufacturers to be controlled via the same interface. To control cameras from a specific manufacturer, the paths to the CTI files supplied by the manufacturer must be entered line by line in the test bench configuration. You can mix different manufacturers and interfaces. The required CTI files are often located in the installation directory of the manufacturer’s software:
Example:
C:\Program Files\IDS\ids_peak\ids_u3vgentl\64\ids_u3vgentlk.cti
C:\Program Files\IDS\ids_peak\ids_u3vgentl\64\ids_u3vgentlk.cti
C:\Program Files\IDS\ids_peak\ids_ueyegentl\64\ids_ueyegentl.cti
C:\Program Files\Basler\pylon 7\Runtime\x64\ProducerGEV.cti
C:\Program Files\Basler\pylon 7\Runtime\x64\ProducerU3V.cti
Properties 🛈¶
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
CTI files |
text |
Paths to your camera\’s CTI files. E.g. “C:\Program Files\Basler\pylon 7\Runtime\x64\ProducerU3V.cti”. One path per line. |
|||
Timeout for tool call ❲in sec.❳ |
‘600’ |
string |
工具调用被中止前的超时时间。 |