Port MODELACCESS - DEFAULT¶
Model access
Stimulation¶
Restrictions:
不支持激励输入信号。
由 STI 文件中的 DataFileSegment 引用的 Trace 文件不会由 ecu.test 自动转换。
Supported execution modes¶
另请参见:时间模式的特殊说明
Preferred time source/mode: Continuous simulation time
- Real-time:
To use the Real-time mode it is necessary that the simulation speedup in the SILVER project properties (F3) is set to 1.00 or that the explicit Real-time mode is enabled. Moreover it is necessary that the computer running SILVER has sufficient power to ensure the execution of the simulation in real-time. To use real-time mode, the Test configuration in the Execution tab must be configured as the source ‘real time’.
- Stepwise simulation time:
To use the stepwise simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to ‘stepwise’. Wait-until-true expressions are evaluated - if possible - by the tool. If the tool cannot evaluate them, the evaluation will be done by ecu.test. This can lead to lower performance. Invalid expressions are only noted in the log if the log level is set to “Maximum”.
- Continuous simulation time:
If the continuous mode is used, ecu.test will extend the SILVER Experiment by a further python module in order to transfer the time stamps. This should not be saved manually, because it will be automatically configured on creation. The time stamp resolution can be configured at the port. To use the continuous simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to ‘continuous’.
Properties 🛈¶
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
ecu.test/Silver configuration file |
string |
Optional. This file defines descriptions to map in SILVER available scalars as vectors or matrices in ecu.test. |
|||
Reset simulation |
‘never’ |
[‘on test start’, ‘never’] 显示值:
|
string |
Specifies when the simulation is reset. On test start: The simulation will be reset before starting a test. Never: The simulation will not be reset. |
|
Enable simulation control |
☐ |
bool |
If True, the simulation will be started after connecting with SILVER and stopped after disconnecting |
||
Port used for streaming the current model time |
2370 |
int |
This port is used by a socket connecting to ecu.test, streaming the current model time from SILVER |
||
MacroStepMultiplier applied for model-time streaming |
1 |
int |
In order to decrease the impact on the simulation it is possible to set down the interval used for delivering timestamps to ecu.test. Setting a number n will result in every n-th timestamp to be sent (instead of each). |
||
Use SILVER’s internal model-time for recordings |
☐ |
bool |
Uses SILVER’s internal model-time as start time for recordings instead of starting at 0. |
Jobs 🛈¶
GetSimulationTime¶
Returns the current time stamp of the simulation in SILVER
Parameterization
返回值
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
result |
float |
ReadVariable¶
Reading a variable
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
VariableName |
string |
Name of quantity to be read |
WriteVariable¶
Writing a variable
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
Value |
int |
Value to write into a model variable |
|||
VariableName |
string |