Port FAILURESIM - FIU¶
ES4440 port
Stimulation¶
此端口不具备激励能力。
Properties 🛈¶
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
Wireharness file |
string |
Wireharness file path, absolute or relative to the Wireharness file directory |
|||
High current channel |
‘UBatt_A’ |
[‘UBatt_A’, ‘UBatt_B’] |
string |
HighCurrent channel. High voltage channel is selected automatically. |
Jobs 🛈¶
CurrentMeasurement¶
Routes the channel via the ‘Current’ connectors on the front panel to measure the current
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
-1 |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
||
pin |
[ONLINE] |
string |
Complete pin name (ecu/pin) |
GetLastErrorSimulationAnswer¶
Provides the at last received answer of the FIU
Parameterization
返回值
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
response |
object |
Tuple of bytes, whose values each represent a byte of the received answer. |
IDN¶
Module identification
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
deviceKey |
‘Standalone’ |
string |
Device name “Standalone”, “Master” or “Slave1”, …, “Slave14” |
OpenLoad¶
Open load
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
|||
pin |
[ONLINE] |
string |
Complete pin name (ecu/pin) |
OpenLoad_Realtime¶
Open load (real-time)
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
|||
pin |
[ONLINE] |
string |
Complete pin name (ecu/pin) |
Pin2Pin¶
Pin2Pin. Load can only be set for high voltage channels
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
|||
load |
☐ |
bool |
Load only for high voltage channels |
||
pin1 |
[ONLINE] |
string |
First pin name |
||
pin2 |
[ONLINE] |
string |
Second pin name |
Pin2Pin_Realtime¶
Pin2Pin (realtime)
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
|||
pin1 |
[ONLINE] |
string |
First pin name |
||
pin2 |
[ONLINE] |
string |
Second pin name |
||
resistor |
int |
Resistance in Ohms (>0) |
PullUp_PullDown¶
Load, resistor and short-circuit (realtime)
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
|||
load |
☐ |
bool |
Load |
||
pin |
[ONLINE] |
string |
Complete pin name (ecu/pin) |
||
resistor |
int |
Resistance in Ohms (>0) |
|||
voltageRail |
[‘UBATT’, ‘GROUND’] |
string |
Voltage rail |
ResetAllErrors¶
Resets all active errors.
RInline¶
Resistor (real-time)
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
|||
pin |
[ONLINE] |
string |
Complete pin name (ecu/pin) |
||
resistor |
int |
Resistance in Ohms (>0) |
Shortcut¶
Short-circuit
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
|||
load |
☐ |
bool |
Load |
||
pin |
[ONLINE] |
string |
Complete pin name (ecu/pin) |
||
voltageRail |
[‘UBATT’, ‘GROUND’] |
string |
Voltage rail |
Shortcut_Realtime¶
Short-circuit (realtime)
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
duration |
int |
Duration in ms (following errors will be delayed until this time has passed) or -1 for permanent activation (following errors will not be blocked; “ResetAllErros” has to be called). |
|||
load |
☐ |
bool |
Load |
||
pin |
[ONLINE] |
string |
Complete pin name (ecu/pin) |
||
voltageRail |
[‘UBATT’, ‘GROUND’] |
string |
Voltage rail |
TestFuses¶
Returns the fuse state E1 to E5
Parameterization
Parameter
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
deviceKey |
‘Master’ |
string |
Device name “Master” or “Slave1”, …, “Slave14” |
返回值
Name |
在以下情况下可用 |
默认值 |
有效值 |
Type |
Description |
|---|---|---|---|---|---|
fuseStates |