Port MODELACCESS - NO_HILAPI

without HiL-API access. This port type does not support stimulation.

Stimulation

此端口不具备激励能力。

Supported execution modes

另请参见:时间模式的特殊说明

Preferred time source/mode: Real-time

Real-time:

To use real-time mode, the Test configuration in the Execution tab must be configured as the source ‘real time’.

Stepwise simulation time:

To use the stepwise simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to ‘stepwise’.

Info

The following modes are not supported: Continuous simulation time

Name

在以下情况下可用

默认值

有效值

Type

Description

Platform name

‘SCALEXIO’

string

Name of the platform as specified in the Experiment. Alternatively the platform name in the ControlDesk Platform Management can be used.

dSPACE RTT Version

‘<auto>’

[‘1.7’, ‘1.8’, ‘1.9’, ‘2.0’, ‘2.1’, ‘2.2’, ‘2.3’, ‘2.4’, ‘2.5’, ‘2.6’, ‘3.0’, ‘3.1’, ‘3.2’, ‘3.3’, ‘3.4’, ‘4.0’, ‘4.1’, ‘4.2’, ‘4.3’, ‘4.4’, ‘5.0’, ‘5.1’, ‘5.2’, ‘22.2’, ‘23.1’, ‘23.2’, ‘24.1’, ‘<auto>’]

string

Product version of dSPACE Real-Time Testing

在线模型查询

☐

bool

(取消)激活用于由 Test Configuration 在线查询模型信息的接口,包括可用参数和信号列表。如果启用该属性,则在运行时从工具查询这些信息;如果禁用,则改为解析模型文件。

Model file

uri

Path relative to the model directory

Loading behavior on reduced compatibility

‘cancel’

[‘cancel’, ‘fix and download’, ‘ignore’]


显示值:

  • ‘cancel’: ‘Cancel’

  • ‘fix and download’: ‘Fix reduced compatibility and download’

  • ‘ignore’: ‘Ignore reduced incompatibility’

string

Behavior of loading on reduced compatibility between model and SCALEXIO System

Download model

‘download’

[‘download’, ‘no download’]


显示值:

  • ‘download’: ‘Download always’

  • ‘no download’: ‘Do not download’

string

Download model automatically

Start model

‘start’

[‘start’, ‘no start’]


显示值:

  • ‘start’: ‘Start’

  • ‘no start’: ‘Do not start’

string

Start model automatically after loading (only SCALEXIO)

Recording task

‘Tool-Default’

string

Recording acquisition rate to use as fallback, if there is no given acquisition rate for the test value (’*’ and ‘?’ may be used as wildcards).

“Tool-Default” uses the first available acquisition rate.

Use common recorder

☐

bool

Defines whether signals of this port should be recorded together with those of other ports of this tool. This guarantees a common time base and creates a single recording file. Otherwise a separate recording file is created.

ReadVariable

Read model variables

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

VariablePath

uri

full model path

WriteVariable

Write model variables

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

Value

string

VariablePath

uri

full model path